Abbott ARCHITECT i1000SR Hormone Analyzer
Introduction
The Abbott ARCHITECT i1000SR is an automated immunoassay analyzer designed for a wide range of hormone and immunoassay testing applications. The system uses Chemiluminescent Microparticle Immunoassay (CMIA) technology to provide reliable and reproducible laboratory results.
The ARCHITECT i1000SR can be used in clinical diagnostic laboratories, hospitals, medical centers, and other laboratories that require an automated solution for routine and specialized hormone and immunoassay testing.
Abbott ARCHITECT i1000SR Testing Technology
The ARCHITECT i1000SR uses Chemiluminescent Microparticle Immunoassay (CMIA) technology. This method combines microparticle-based immunoassay techniques with chemiluminescent detection to measure a broad range of analytes.
CMIA technology provides a sensitive and efficient method for performing different immunoassay tests, depending on the available reagents and assay menu.
Technology Overview
| Feature | Description |
|---|---|
| Immunoassay Technology | Chemiluminescent Microparticle Immunoassay (CMIA) |
| Detection Method | Chemiluminescent detection |
| Application | Hormone and immunoassay testing |
| Assay Range | Depends on available ARCHITECT reagents and assay menu |
| System Type | Automated immunoassay analyzer |
Tests Performed by Abbott ARCHITECT i1000SR
Depending on the available assay menu and reagents, the Abbott ARCHITECT i1000SR can be used for several categories of laboratory testing.
| Test Category | Examples / Applications |
|---|---|
| Thyroid Testing | TSH, T3, T4 |
| Hormone Testing | Various hormone assays |
| Fertility Testing | Fertility-related hormone tests |
| Vitamin Testing | Selected vitamin assays |
| Tumor Markers | Selected tumor marker assays |
| Infectious Disease Testing | Selected infectious disease assays |
| Anemia-Related Testing | Selected anemia-related assays |
| Metabolic Testing | Selected metabolic-related assays |
| Cardiac Testing | Selected cardiac markers |
The exact test menu depends on the system configuration, software version, assay availability, and Abbott reagents used by the laboratory.
Key Features of Abbott ARCHITECT i1000SR
The ARCHITECT i1000SR incorporates automated processes designed to support efficient immunoassay testing in clinical laboratory environments.
| Key Feature | Description |
|---|---|
| Analyzer Type | Automated immunoassay analyzer |
| Technology | CMIA |
| Primary Applications | Hormone and immunoassay testing |
| Assay Capability | Supports a broad range of assays |
| Laboratory Use | Clinical diagnostic laboratories, hospitals, and medical centers |
| Testing Applications | Routine and specialized immunoassay testing |
| Laboratory Integration | Supports LIS connectivity in supported configurations |
| Workflow | Automated handling of major testing processes |
| Reagents | Dedicated ARCHITECT assay reagents |
| System Integration | Can be integrated into laboratory workflows alongside compatible laboratory systems |
Sample Types
The appropriate sample type depends on the specific assay and reagent being used. Common sample types may include serum and plasma.
Because sample requirements can vary between individual assays, the manufacturer’s instructions for the specific assay should always be reviewed before testing.
Abbott ARCHITECT i1000SR Applications
The ARCHITECT i1000SR can support laboratories that perform a variety of immunoassay applications. Its automated workflow and CMIA technology make it suitable for laboratories that need to process different types of immunoassay tests using compatible reagents.
Typical application areas may include:
- Thyroid function testing
- Hormone analysis
- Fertility testing
- Vitamin testing
- Tumor marker analysis
- Selected infectious disease testing
- Selected metabolic testing
- Selected anemia-related testing
- Selected cardiac marker testing
The available applications are determined by the assay menu and reagents configured for the individual analyzer.
Buying Abbott ARCHITECT i1000SR
When purchasing an Abbott ARCHITECT i1000SR, the technical condition of the analyzer should be considered alongside the purchase price.
This is particularly important when purchasing a used or refurbished system. A detailed evaluation can help determine the actual operating condition of the analyzer and identify potential maintenance requirements.
Important Factors When Purchasing a Used or Refurbished i1000SR
| Evaluation Item | What Should Be Checked |
|---|---|
| Technical Condition | Overall operating condition of the analyzer |
| Sample Handling System | Proper sample movement and handling |
| Washing System | Performance and condition of the washing components |
| Incubation System | Proper operation and temperature control |
| Detection System | Detection performance and related components |
| Software | Software version, functionality, and system compatibility |
| Run Count | Total number of tests or operational history where available |
| Consumables | Availability and condition of required consumables |
| Spare Parts | Availability of replacement parts |
| Calibration | Calibration status and requirements |
| Maintenance History | Previous maintenance and service records |
| Accessories | Included accessories and compatible components |
Ervin Danesh Azma provides laboratory equipment supply and related services, including equipment installation, setup, training, technical support, and maintenance, depending on the equipment and laboratory requirements.
Abbott i1000SR Price
The price of an Abbott ARCHITECT i1000SR depends on several factors. New, used, and refurbished systems can have significantly different prices depending on their condition and configuration.
| Price Factor | Description |
|---|---|
| System Condition | New, used, or refurbished |
| Operating Condition | Current technical and functional condition |
| Run Count | Operational history and number of completed tests where available |
| Year of Manufacture | Age of the analyzer |
| Accessories | Included accessories and additional components |
| Refurbishment Status | Extent and quality of refurbishment |
| Spare Parts | Availability of required replacement parts |
| Consumables | Availability and cost of compatible consumables |
| Configuration | Installed software, modules, and system configuration |
| Market Conditions | Current availability and market demand |
For an accurate current price, the exact condition, configuration, and available accessories of the analyzer should be evaluated.
Abbott i1000SR Repair and Technical Service
Regular maintenance and professional technical service are important for maintaining the performance and reliability of an automated immunoassay analyzer.
Depending on the condition of the system and the type of service required, technical support may include the following:
| Technical Service | Description |
|---|---|
| Troubleshooting | Identification and resolution of system errors |
| Preventive Maintenance | Routine inspection and maintenance |
| Mechanical Inspection | Checking mechanical components and moving parts |
| Electronic Inspection | Evaluation of electronic components and system functions |
| Sample Handling Check | Inspection of sample handling mechanisms |
| Washing System Inspection | Checking washing components and operation |
| Calibration | Calibration procedures according to applicable requirements |
| Error Diagnosis | Identification of system errors and operational problems |
| Parts Replacement | Replacement of damaged or worn components |
| Consumable Replacement | Replacement of required consumables |
Proper preventive maintenance can help laboratories reduce unexpected downtime and maintain consistent analyzer performance.
Why Technical Evaluation Matters
For used or refurbished laboratory analyzers, technical evaluation is an important part of the purchasing process. The physical condition of the analyzer alone does not necessarily indicate its actual operating performance.
A comprehensive evaluation should consider the analyzer’s operational history, software, sample handling system, washing and incubation systems, detection components, calibration status, consumables, and availability of spare parts.
Laboratories should also consider the availability of technical support after installation, particularly when the analyzer is intended for continuous routine diagnostic use.
Conclusion
The Abbott ARCHITECT i1000SR is an automated immunoassay analyzer based on Chemiluminescent Microparticle Immunoassay (CMIA) technology and designed for a broad range of hormone and immunoassay applications.
The system can support various testing areas, including thyroid testing, hormone analysis, fertility-related testing, vitamin testing, tumor markers, selected infectious disease assays, metabolic testing, anemia-related testing, and selected cardiac markers, depending on the available assay menu and reagents.
For laboratories considering a used or refurbished Abbott ARCHITECT i1000SR, factors such as technical condition, run count, reagent availability, consumables, spare parts, software, installation, maintenance history, and after-sales technical support should be carefully evaluated.
Ervin Danesh Azma provides laboratory equipment supply and related services, including installation, setup, training, technical support, and maintenance according to laboratory requirements.





Free Consultation
Fast Delivery




Reviews